LEMO Ventilator Power Extend Connection Harness
Medical power wiring harnesses are widely used in medical equipment, such as operating tables, X-ray machines, MRI, ultrasound machines, electrocardiographs, etc.
Currently, phototherapy equipment is widely used in the medical field. As an important part of phototherapy equipment, medical power cord harness delivers light energy into the patient’s body to help the patient treat the disease.
Customize the ventilator power wiring harness according to your drawing or sample requirements.
Wire: UL2661;
ตัวเชื่อมต่อ: German Lemo (LEMO);
Iron powder core (magnetic ring): LAIRD;
Customization: Customize wire harness according to customer requirements, length, specifications, color, etc.;
Application: internal/external connecting lines of medical equipment;
Customer case: TATA| XP| iRay;
Name: Ventilator power connection harness;
Processing technology: welding, injection molding, riveting, glue filling;
Whether to process and customize: Customize the length, specification, color, etc. of the wire harness according to customer requirements;
ตัวเชื่อมต่อ: German LEMO 90° aviation plug;
Wire: 26AWG tinned copper (satisfies ≥5000 bending times);
Iron powder core: LAIRD (implementing WI-QA-038 standard) to solve anti-interference (EMI, EMC);
Withstand voltage: DC1000V, 3 seconds;
Insulation resistance: ≥100M ohm;
On-resistance: ≤2 ohms;
Shielding (min): 75 dB (10 MHz)
Dielectric strength: DC: 500V/1 minute;
Connector salt spray corrosion: >1000 ชั่วโมง
Product certification: UL, IPC620, REACH, ROHS2.0, MASDS;
Application areas: internal/external connecting lines of medical equipment;
Company honors and qualifications: National High-tech Enterprise, UL, IPC620, ISO9001, ISO14000, ISO13485, IATF16949, etc.
Purpose
Medical power wiring harnesses are widely used in medical equipment, such as operating tables, X-ray machines, MRI, ultrasound machines, electrocardiographs, etc.Currently, phototherapy equipment is widely used in the medical field. As an important part of phototherapy equipment, medical power cord harness delivers light energy into the patient’s body to help the patient treat the disease.
Life support equipment includes ventilators, pulse oximeter, electrocardiograph, etc. The application of these devices is inseparable from medical power wiring harnesses.
Maintenance methods
The environment in which medical power cord harnesses are used should be kept dry, clean, and ventilated. When working, care should be taken to avoid smoking, oxygen inhalation, etc., and try to avoid the wiring parts of the equipment being contaminated by oil, moisture and other substances.When using the medical power cord harness, it should be used in accordance with the instructions. Do not pull on the wire harness forcefully, and do not repeatedly plug and unplug connectors. At the same time, care should be taken during maintenance to avoid wire breakage, thermal damage, mechanical tearing, etc.
Regular inspection is also an important part of maintaining medical power wiring harness. During inspection, you should pay attention to whether there are problems such as metal oxidation at the wiring harness port, whether the power cord is worn or hardened, and whether there are turns or creases. Check whether the entire wiring harness is cracked, the wires are frayed, or the wiring harness sheath is broken. If abnormalities are found, timely maintenance or replacement of original parts is required.
Cleaning is also one of the keys to maintaining medical power wiring harnesses. To protect the connectors and wires on the wiring harness from being corroded or dirty, clean them with clean water or detergent. At the same time, liquid should be avoided from entering the wiring harness port during cleaning.
The fire and explosion protection of medical power wiring harness is one of the important factors to ensure the safety of use. ดังนั้น, avoid contact of the wiring harness with sources of ignition or contact with flammable materials.
In summary, medical power harnesses are widely used in medical equipment, phototherapy equipment, life support equipment and other fields. At the same time, in terms of maintenance, relevant maintenance guidelines should be strictly followed to avoid mechanical damage, moisture, wear, etc., so as to ensure the long-term use effect and safety of the product.
ติดต่อเรา
กำลังรออีเมลของคุณ, เราจะตอบกลับคุณภายใน 12 ชั่วโมงด้วยข้อมูลอันมีค่าที่คุณต้องการ.
RELATED PRODUCTS
automating Robot-Assisted Wiring Harness set
The process flow for manufacturing robot wire harnesses typically includes the following steps:
Design and planning: Design the layout, connection methods and electrical characteristics of the wiring harness according to the needs and functional requirements of the robot. Consider factors such as wire cross-sectional area, length, color coding and number of conductors.
Material preparation: Select high-quality wires, ขั้วต่อ, protective sleeves and other accessories suitable for robotic applications. Ensure materials comply with relevant industry standards and specifications.
OEM Male to Female RC-HDMI Connection Cable
High Speed HDMI cable is the abbreviation of High Definition Multimedia Interface Cable. It can transmit uncompressed high-definition video and multi-channel audio data with high quality, and the maximum data transmission speed is 5Gbps. At the same time, there is no need to perform digital/analog or analog/digital conversion before signal transmission, which can ensure the highest quality audio and video signal transmission.